trusted seller
Kirloskar Two Stage Monobloc Pumpset type KDT

Kirloskar Two Stage Monobloc Pumpset type KDT

Product Details:

  • Flow Rate Up to 96 m/hr
  • Theory Centrifugal Pump
  • Material Cast Iron/Cast Steel/SS
  • Structure Monobloc, Two Stage
  • Suction Type Single Suction
  • Volute Type Double Volute
  • Nozzle Location End Suction, Top Discharge
  • Click to view more
X

Kirloskar Two Stage Monobloc Pumpset type KDT Price And Quantity

  • 1 Piece

Kirloskar Two Stage Monobloc Pumpset type KDT Product Specifications

  • Single Suction
  • Electric
  • Cast Iron/Cast Steel/SS
  • End Suction, Top Discharge
  • Double Volute
  • AC Power
  • Water supply, firefighting, irrigation, HVAC systems, industrial usages
  • 2900 RPM
  • Monobloc, Two Stage
  • Up to 96 m/hr
  • Up to 10 kg/cm
  • 100 mm x 80 mm (varies with model)
  • Centrifugal Pump
  • Horizontal
  • Up to 65C

Kirloskar Two Stage Monobloc Pumpset type KDT Trade Information

  • as per oder Per Week
  • as per oder Week
  • All India

Product Description


Kirloskar Two Stage Monobloc Pumpset type KDT



Features:


  • Flatter efficiency curve for efficient operation

  • Designed to prevent overloading and motor burning

  • Designed for automatic air release during priming

  • Efficiency at par with international pumps

  • Dynamically balanced rotating parts ensuring minimum vibration during running

  • Class B/ F insulation

  • Replaceable wearing parts

  • Models with IP55 protection



Applications:


  • Air conditioning system

  • Refrigeration

  • Cooling towers

  • Fire fighting

  • Industries for clear water handling at high pressures



Specifications:


  • Capacity up to 20 lps

  • Head up to 110 m

  • Power rating 3.7 to 15 kW (5 to 20 HP)

  • Voltage 300-440 V (Three Phase)



Superior Pump Design for Demanding Applications

The KDT Monobloc pumpset leverages a two-stage centrifugal mechanism with a dynamically balanced closed impeller, delivering high efficiency and stable performance. Its double volute and end suction design minimize radial loads and facilitate reliable operation even in demanding scenarios.


Versatile Construction and Material Options

Available in cast iron, cast steel, and stainless steel variants, this pumpset adapts to a variety of industrial, municipal, and firefighting uses. The monobloc structure ensures a compact footprint and ease of installation, while the gland packed or mechanical seal options offer flexibility in sealing arrangements.


Reliable Performance and Certification

Engineered to conform to IS: 9968 standards, KDT pumpsets are rigorously tested for durability and efficiency. With IP55 protection and F class insulation, the pumps offer optimal performance under a range of ambient and operational conditions, ensuring longevity and safety in use.

FAQs of Kirloskar Two Stage Monobloc Pumpset type KDT:


Q: How is the Kirloskar KDT Two Stage Monobloc Pump installed and commissioned?

A: The KDT pumpset is foot mounted and horizontally oriented for simple installation. Since the pump and motor are on a common shaft (monobloc), precise alignment is built-in, reducing setup time. Standard power supply of 415 V 10% and three-phase AC are required. A qualified technician should commission the pump according to IS: 9968 and manufacturers guidelines.

Q: What are the main applications for this pumpset?

A: This pumpset is suitable for a wide range of applications including water supply systems, firefighting, irrigation, HVAC circulation, and industrial processes. Its high head and flow rate capacity, plus robust construction, make it ideal for both urban and rural requirements.

Q: When should gland packed versus mechanical seal arrangements be chosen?

A: Gland packed sealing is generally selected for relatively clean water applications with routine maintenance access, offering lower initial cost. Mechanical seals are preferable for handling slightly dirty or corrosive fluids, or when zero leakage is critical, providing increased operational reliability with minimal maintenance.

Q: Where is the suction and discharge located on the KDT pumpset?

A: The pumpset features an end suction and top discharge configuration. The suction nozzle intake is at the pumps end, making pipe connection straightforward, while the discharge is conveniently located at the top, ideal for effective system integration.

Q: What process or operating conditions can the KDT handle safely?

A: KDT pumps are engineered to handle water or similar fluids at temperatures up to 65C, pressures up to 10 kg/cm, and heads up to 95 meters. The unit can operate continuously at 2900 RPM in accordance with operating instructions, thanks to its IP55 motor protection and F class insulation.

Q: How does the monobloc structure benefit the user?

A: The monobloc design eliminates coupling misalignment and reduces vibration, resulting in quieter, smoother operation and easy maintenance. The reduced number of mounting parts and simplified construction allow faster installation and enhance reliability, minimizing downtime.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Kirloskar ' category



Back to top